Skip to content

I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • CS-04.01.06

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Construction - Continuously Viewed Carrier

    &lt;VulnDiscussion&gt;A PDS that is not constructed and configured as required could result in the undetected interception of classified informatio...
    Rule High Severity
  • CS-04.01.07

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Construction - Tactical Environment Application

    &lt;VulnDiscussion&gt;A PDS that is not constructed and configured as required could result in the undetected interception of classified informatio...
    Rule High Severity
  • CS-04.01.08

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Construction - Alarmed Carrier

    &lt;VulnDiscussion&gt;A PDS that is not constructed and configured as required could result in the covert or undetected interception of classified ...
    Rule High Severity
  • CS-04.02.01

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Construction - Visible for Inspection and Marked

    &lt;VulnDiscussion&gt;A PDS that is not completely visible for inspection and easily identified cannot be properly inspected and monitored as requi...
    Rule Medium Severity
  • CS-04.02.02

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Construction - Sealed Joints

    &lt;VulnDiscussion&gt;A PDS that is not constructed and sealed as required could result in the undetected interception of classified information. ...
    Rule Medium Severity
  • CS-05.03.01

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Documentation - Signed Approval

    &lt;VulnDiscussion&gt;A PDS that is not approved could cause an Information System Security Manager (ISSM), Authorizing Official (AO) and other con...
    Rule Low Severity
  • CS-05.03.02

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Documentation - Request for Approval Documentation

    &lt;VulnDiscussion&gt;A PDS that is not approved could cause an Information System Security Manager (ISSM), Authorizing Official (AO) and other con...
    Rule Low Severity
  • CS-06.02.01

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Monitoring - Daily (Visual) Checks

    &lt;VulnDiscussion&gt;A PDS that is not inspected, monitored and maintained as required could result in undetected access, sabotage or tampering of...
    Rule Medium Severity
  • CS-06.02.02

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Monitoring - Reporting Incidents

    &lt;VulnDiscussion&gt;A PDS that is not inspected, monitored and maintained as required could result in undetected access, sabotage or tampering of...
    Rule Medium Severity
  • CS-06.03.01

    <GroupDescription></GroupDescription>
    Group
  • Protected Distribution System (PDS) Monitoring - Technical Inspections

    &lt;VulnDiscussion&gt;A PDS that is not inspected, monitored and maintained as required could result in undetected access, sabotage or tampering of...
    Rule Low Severity