Protected Distribution System (PDS) Construction - Continuously Viewed Carrier

An XCCDF Rule

Description

<VulnDiscussion>A PDS that is not constructed and configured as required could result in the undetected interception of classified information. A continuously viewed PDS may not be in a physically hardened carrier and the primary means of protection is continuous observation and control of the unencrypted transmission line. If not maintained under continuous observation an attacker (insider or external) could have an opportunity to tap and intercept unencrypted communications on the exposed cable. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 35.c. DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016 Chapter 5, Section 4, paragraphs 5-402.c. and 5-403 DoD Manual 5200.01, Volume 3, 24 February 2012, SUBJECT: DoD Information Security Program: Protection of Classified Information, Encl 4, para 3.b. and 4.a. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: PE-4, SC-7, and SC-8 CNSSI No. 7003, September 2015, Protected Distribution Systems (PDS), Section IV, paragraph 7. and Section X, paragraph 30.e.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-245733r822800_rule
Severity
High
Updated



Remediation - Manual Procedure

Interior or Exterior PDS: Continuously viewed Carrier. This is one of five types of Category 2 PDS allowed IAW the CNSSI 7003. 

There are four requirements that must be met for this type of distribution system:
  
1. The transmission line must be under continuous observation, 24 hours per day (including when non-operational).