Protected Distribution System (PDS) Construction - Alarmed Carrier
An XCCDF Rule
Description
<VulnDiscussion>A PDS that is not constructed and configured as required could result in the covert or undetected interception of classified information. An Alarmed Carrier is one of five types of Category 2 PDS. It is the most suitable alternative to Hardened and Continuously Viewed PDS (internal facility PDS options), when the unencrypted data transmission line is concealed above suspended ceilings, below raised floors, between walls or in any situation where the line is not visible for inspection. In lieu of daily visual inspections the functionality of the PDS alarm must be tested at least weekly - as based on guidance in the CNSSI 7003. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 35.c. DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016 Chapter 5, Section 4, paragraphs 5-402.c., 5-403 and Section 9 DoD Manual 5200.01, Volume 3, 24 February 2012, SUBJECT: DoD Information Security Program: Protection of Classified Information: Encl 4, para 3.b. and 4.a.; Appendix to Encl 3, para 2 & 2.f.(2); DoD Manual 5200.02 Procedures for the DoD Personnel Security Program (PSP), 3 April 2017 NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: PE-4, PE-6(1), (2) & (3), SC-7, and SC-8 CNSSI No.7003, September 2015, Protected Distribution Systems (PDS), Section IV, paragraph 7. and Section X, paragraph 30.d.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-245735r822802_rule
- Severity
- High
- Updated
Remediation - Manual Procedure
An Alarmed PDS is one of five types of Category 2 PDS IAW the CNSSI 7003. It is a suitable alternative for the two types of interior PDS, which are Hardened Carrier or Continuously Viewed Carrier. It should be used when the unencrypted data transmission line is concealed above suspended ceilings, below raised floors, between walls or in any situation where the line is not visible for inspection. In lieu of daily visual inspections the functionality of the PDS alarm must be tested at least weekly - or as based on guidance in the CNSSI 7003.
Ensure unencrypted SIPRNet data cables are installed in a carrier properly configured as an "Alarmed Carrier" IAW the following guidelines:
1. Ideally the carrier will be constructed of solid electrical metallic tubing (EMT), ferrous conduit or pipe, or rigid-sheet steel ducting, utilizing elbows, couplings, nipples, and connectors of the same material. Connectors need not be permanently sealed in an alarmed carrier. As a minimum the carrier may consist of any material equal to or better than standards for a "Simple PDS" (e.g., wood, PVT, EMT, ferrous conduit. The key to determining the appropriateness of a PDS carrier is its suitability for supporting the functionality of the approved alarm sensor, which provides a means to detect tampering and/or breach of the actual PDS carrier - *not a breach of the space surrounding the carrier. An IDS sensor capable of detecting changes in carrier air pressure is an example of an acceptable detection methodology.