Skip to content

I - Mission Critical Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000001-NDM-000200

    Group
  • Forescout must limit the number of concurrent sessions to one for each administrator account.

    Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administr...
    Rule Low Severity
  • SRG-APP-000317-NDM-000282

    Group
  • Forescout must terminate the account of last resort password when members with access to the password leave the group.

    A shared/group account credential is a shared form of authentication that allows multiple individuals to access the network device using a single account. If shared/group account credentials are no...
    Rule Medium Severity
  • SRG-APP-000148-NDM-000346

    Group
  • Forescout must be configured with only one web account and one CLI account of last resort with limited access and used only when the authentication server is unavailable.

    Authentication for administrative (privileged-level) access to the device is required at all times. An account can be created on the device's local database for use when the authentication server i...
    Rule Medium Severity
  • SRG-APP-000065-NDM-000214

    Group
  • Forescout must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must lock out the user account from accessing the device for 15 minutes.

    By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
    Rule Medium Severity
  • SRG-APP-000068-NDM-000215

    Group
  • Forescout must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

    Display of the DoD-approved use notification before granting access to the application ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executive ...
    Rule Low Severity