Skip to content

I - Mission Critical Sensitive

Rules and Groups employed by this XCCDF Profile

  • SRG-OS-000080

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Install data sets are not properly protected.

    &lt;VulnDiscussion&gt;ROSCOE Install data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to ...
    Rule Medium Severity
  • SRG-OS-000259

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE STC data sets are not properly protected.

    &lt;VulnDiscussion&gt;ROSCOE STC data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to prop...
    Rule Medium Severity
  • SRG-OS-000018

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE resources must be properly defined and protected.

    &lt;VulnDiscussion&gt;ROSCOE can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control ...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Started Task name is not properly identified / defined to the system ACP.

    &lt;VulnDiscussion&gt;Products that require a started task will require that the started task be restricted to certain resources, datasets and othe...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.

    &lt;VulnDiscussion&gt;Access to product resources should be restricted to only those individuals responsible for the application connectivity and ...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE is not properly defined to the Facility Matrix Table for Top Secret.

    &lt;VulnDiscussion&gt;Improperly defined security controls for the Product could result in the compromise of the network, operating system, and cus...
    Rule Medium Severity
  • SRG-OS-000309

    <GroupDescription></GroupDescription>
    Group
  • Resouce Class ROSRES is not defined or active in the ACP.

    &lt;VulnDiscussion&gt;Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS opera...
    Rule Medium Severity
  • SRG-OS-000018

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE configuration/parameter values are not specified properly.

    &lt;VulnDiscussion&gt;Product configuration/parameters control the security and operational characteristics of products. If these parameter values...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules