  • SRG-NET-000148

    <GroupDescription></GroupDescription>
    Group
  • The layer 2 switch must uniquely identify all network-connected endpoint devices before establishing any connection.

    &lt;VulnDiscussion&gt;Controlling LAN access via 802.1x authentication can assist in preventing a malicious user from connecting an unauthorized PC...
    Rule High Severity
  • SRG-NET-000168

    <GroupDescription></GroupDescription>
    Group
  • The layer 2 switch must authenticate all VLAN Trunk Protocol (VTP) messages with a hash function using the most secured cryptographic algorithm available.

    &lt;VulnDiscussion&gt;VLAN Trunk Protocol (VTP) provides central management of VLAN domains, thus reducing administration in a switched network. Wh...
    Rule Medium Severity
  • SRG-NET-000193

    <GroupDescription></GroupDescription>
    Group
  • The layer 2 switch must manage excess bandwidth to limit the effects of packet flooding types of denial of service (DoS) attacks.

    &lt;VulnDiscussion&gt;Denial of service is a condition when a resource is not available for legitimate users. Packet flooding DDoS attacks are refe...
    Rule Medium Severity
  • SRG-NET-000235

    <GroupDescription></GroupDescription>
    Group
  • The layer 2 switch must be configured to fail securely in the event of an operational failure.

    &lt;VulnDiscussion&gt;If the switch fails in an unsecure manner (open), unauthorized traffic originating externally to the enclave may enter or the...
    Rule Medium Severity
  • SRG-NET-000331

    <GroupDescription></GroupDescription>
    Group
  • The layer 2 switch must provide the capability for authorized users to select a user session to capture.

    &lt;VulnDiscussion&gt;Without the capability to select a user session to capture/record or view/hear, investigations into suspicious or harmful eve...
    Rule Medium Severity