Skip to content

I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-NET-000193-L2S-000020

    Group
  • The Arista MLS layer 2 switch must be configured for Storm Control to limit the effects of packet flooding types of denial-of-service (DoS) attacks.

    Denial of service is a condition when a resource is not available for legitimate users. Packet flooding distributed DoS (DDoS) attacks are referred to as volumetric attacks and have the objective o...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000021

    Group
  • The Arista MLS switch must have Root Guard enabled on all switch ports connecting to access layer switches and hosts.

    Spanning Tree Protocol (STP) does not provide any means for the network administrator to securely enforce the topology of the switched network. Any switch can be the root bridge in a network. Howev...
    Rule Low Severity
  • SRG-NET-000362-L2S-000022

    Group
  • The Arista MLS layer 2 switch must have BPDU Guard enabled on all switch ports connecting to access layer switches and hosts.

    If a rogue switch is introduced into the topology and transmits a Bridge Protocol Data Unit (BPDU) with a lower bridge priority than the existing root bridge, it will become the new root bridge and...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000023

    Group
  • The Arista MLS switch must have STP Loop Guard enabled on all nondesignated STP switch ports.

    The Spanning Tree Protocol (STP) loop guard feature provides additional protection against STP loops. An STP loop is created when an STP blocking port in a redundant topology erroneously transition...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000025

    Group
  • The Arista MLS layer 2 switch must have DHCP snooping for all user VLANs to validate DHCP messages from untrusted sources.

    In an enterprise network, devices under administrative control are trusted sources. These devices include the switches, routers, and servers in the network. Host ports and unknown DHCP servers are ...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.