  • SRG-OS-000080

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Install data sets are not properly protected.

    &lt;VulnDiscussion&gt;ROSCOE Install data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to ...
    Rule Medium Severity
  • SRG-OS-000259

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE STC data sets are not properly protected.

    &lt;VulnDiscussion&gt;ROSCOE STC data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to prop...
    Rule Medium Severity
  • SRG-OS-000018

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE resources must be properly defined and protected.

    &lt;VulnDiscussion&gt;ROSCOE can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control ...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Started Task name is not properly identified / defined to the system ACP.

    &lt;VulnDiscussion&gt;Products that require a started task will require that the started task be restricted to certain resources, datasets and othe...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.

    &lt;VulnDiscussion&gt;Access to product resources should be restricted to only those individuals responsible for the application connectivity and ...
    Rule Medium Severity
  • SRG-OS-000104

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE is not properly defined to the Facility Matrix Table for Top Secret.

    &lt;VulnDiscussion&gt;Improperly defined security controls for the Product could result in the compromise of the network, operating system, and cus...
    Rule Medium Severity
  • SRG-OS-000309

    <GroupDescription></GroupDescription>
    Group
  • Resouce Class ROSRES is not defined or active in the ACP.

    &lt;VulnDiscussion&gt;Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS opera...
    Rule Medium Severity
  • SRG-OS-000018

    <GroupDescription></GroupDescription>
    Group
  • ROSCOE configuration/parameter values are not specified properly.

    &lt;VulnDiscussion&gt;Product configuration/parameters control the security and operational characteristics of products. If these parameter values...