Skip to content

I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • WG420

    <GroupDescription></GroupDescription>
    Group
  • Backup interactive scripts on the production web server must be prohibited.

    &lt;VulnDiscussion&gt;Copies of backup files will not execute on the server, but can be read by the anonymous user if special precautions are not t...
    Rule Low Severity
  • WG050

    <GroupDescription></GroupDescription>
    Group
  • The web server service password(s) must be entrusted to the SA or Web Manager.

    &lt;VulnDiscussion&gt;Normally, a service account is established for the web server. This is because a privileged account is not desirable and the ...
    Rule Medium Severity
  • WG040

    <GroupDescription></GroupDescription>
    Group
  • Public web server resources must not be shared with private assets.

    &lt;VulnDiscussion&gt;It is important to segregate public web server resources from private resources located behind the DoD DMZ in order to protec...
    Rule Medium Severity
  • WG060

    <GroupDescription></GroupDescription>
    Group
  • The service account used to run the web service must have its password changed at least annually.

    &lt;VulnDiscussion&gt;Normally, a service account is established for the web service to run under rather than permitting it to run as part of the l...
    Rule Medium Severity
  • WG080

    <GroupDescription></GroupDescription>
    Group
  • Installation of a compiler on production web server must be prohibited.

    &lt;VulnDiscussion&gt;The presence of a compiler on a production server facilitates the malicious user’s task of creating custom versions of progra...
    Rule Medium Severity
  • WA060

    <GroupDescription></GroupDescription>
    Group
  • A public web server, if hosted on the NIPRNet, must be isolated in an accredited DoD DMZ Extension.

    &lt;VulnDiscussion&gt;To minimize exposure of private assets to unnecessary risk by attackers, public web servers must be isolated from internal sy...
    Rule Medium Severity
  • WA070

    <GroupDescription></GroupDescription>
    Group
  • A private web server must be located on a separate controlled access subnet.

    &lt;VulnDiscussion&gt;Private web servers, which host sites that serve controlled access data, must be protected from outside threats in addition t...
    Rule Medium Severity
  • WG190

    <GroupDescription></GroupDescription>
    Group
  • The web server must use a vendor-supported version of the web server software.

    &lt;VulnDiscussion&gt;Many vulnerabilities are associated with old versions of web server software. As hot fixes and patches are issued, these solu...
    Rule High Severity
  • WG200

    <GroupDescription></GroupDescription>
    Group
  • Administrators must be the only users allowed access to the directory tree, the shell, or other operating system functions and utilities.

    &lt;VulnDiscussion&gt;As a rule, accounts on a web server are to be kept to a minimum. Only administrators, web managers, developers, auditors, and...
    Rule High Severity
  • WG220

    <GroupDescription></GroupDescription>
    Group
  • Web administration tools must be restricted to the web manager and the web manager’s designees.

    &lt;VulnDiscussion&gt;All automated information systems are at risk of data loss due to disaster or compromise. Failure to provide adequate protect...
    Rule Medium Severity
  • WG130

    <GroupDescription></GroupDescription>
    Group
  • All utility programs, not necessary for operations, must be removed or disabled.

    &lt;VulnDiscussion&gt;Just as running unneeded services and protocols is a danger to the web server at the lower levels of the OSI model, running u...
    Rule Low Severity
  • WG270

    <GroupDescription></GroupDescription>
    Group
  • The web server’s htpasswd files (if present) must reflect proper ownership and permissions.

    &lt;VulnDiscussion&gt;In addition to OS restrictions, access rights to files and directories can be set on a web site using the web server software...
    Rule Medium Severity
  • WG280

    <GroupDescription></GroupDescription>
    Group
  • The access control files are owned by a privileged web server account.

    &lt;VulnDiscussion&gt;This check verifies that the key web server system configuration files are owned by the SA or Web Manager controlled account....
    Rule Medium Severity
  • WA120

    <GroupDescription></GroupDescription>
    Group
  • Administrative users and groups that have access rights to the web server must be documented.

    &lt;VulnDiscussion&gt;There are typically several individuals and groups that are involved in running a production web site. In most cases, we can ...
    Rule Low Severity
  • WG300

    <GroupDescription></GroupDescription>
    Group
  • Web server system files must conform to minimum file permission requirements.

    &lt;VulnDiscussion&gt;This check verifies that the key web server system configuration files are owned by the SA or Web Manager controlled account....
    Rule Medium Severity
  • WG330

    <GroupDescription></GroupDescription>
    Group
  • A public web server must limit e-mail to outbound only.

    &lt;VulnDiscussion&gt;Incoming E-mail has been known to provide hackers with access to servers. Disabling the incoming mail service prevents this t...
    Rule Medium Severity
  • WG470

    <GroupDescription></GroupDescription>
    Group
  • Wscript.exe and Cscript.exe must only be accessible by the SA and/or the web administrator.

    &lt;VulnDiscussion&gt;Windows Scripting Host (WSH) is installed under either a Typical or Custom installation option of a Microsoft Network Server....
    Rule Medium Severity
  • WG440

    <GroupDescription></GroupDescription>
    Group
  • Monitoring software must include CGI or equivalent programs in its scope.

    &lt;VulnDiscussion&gt;By their very nature, CGI type files permit the anonymous web user to interact with data and perhaps store data on the web se...
    Rule Medium Severity
  • WA140

    <GroupDescription></GroupDescription>
    Group
  • Web server content and configuration files must be part of a routine backup program.

    &lt;VulnDiscussion&gt;Backing up web server data and web server application software after upgrades or maintenance ensures that recovery can be acc...
    Rule Low Severity
  • WG204

    <GroupDescription></GroupDescription>
    Group
  • A web server installation must be segregated from other services.

    &lt;VulnDiscussion&gt;The web server installation and configuration plan should not support the co-hosting of multiple services such as Domain Name...
    Rule Medium Severity
  • WG520

    <GroupDescription></GroupDescription>
    Group
  • Web server and/or operating system information must be protected.

    &lt;VulnDiscussion&gt;The web server response header of an HTTP response can contain several fields of information including the requested HTML pag...
    Rule Low Severity
  • WA155

    <GroupDescription></GroupDescription>
    Group
  • Classified web servers will be afforded physical security commensurate with the classification of its content.

    &lt;VulnDiscussion&gt;When data of a classified nature is migrated to a web server, fundamental principles applicable to the safeguarding of classi...
    Rule High Severity
  • WA230

    <GroupDescription></GroupDescription>
    Group
  • The site software used with the web server must have all applicable security patches applied and documented.

    &lt;VulnDiscussion&gt;The IAVM process does not address all patches that have been identified for the host operating system or, in this case, the w...
    Rule Medium Severity
  • WG275

    <GroupDescription></GroupDescription>
    Group
  • The web server, although started by superuser or privileged account, must run using a non-privileged account.

    &lt;VulnDiscussion&gt;Running the web server with excessive privileges presents an increased risk to the web server. In the event the web server’s ...
    Rule Medium Severity
  • WG355

    <GroupDescription></GroupDescription>
    Group
  • A private web server’s list of CAs in a trust hierarchy must lead to an authorized DoD PKI Root CA.

    &lt;VulnDiscussion&gt;A PKI certificate is a digital identifier that establishes the identity of an individual or a platform. A server that has a c...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules