Skip to content

III - Administrative Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000014

    Group
  • Innoslate must use TLS 1.2, at a minimum, to protect the confidentiality of sensitive data during electronic dissemination using remote access.

    Using older unauthorized versions or incorrectly configuring protocol negotiation makes the gateway vulnerable to known and unknown attacks that exploit vulnerabilities in this protocol. This requ...
    Rule High Severity
  • SRG-APP-000023

    Group
  • Innoslate must provide automated mechanisms for supporting account management functions.

    Enterprise environments make application account management challenging and complex. A manual process for account management functions adds the risk of a potential oversight or other error. A com...
    Rule Medium Severity
  • SRG-APP-000033

    Group
  • Innoslate must enforce approved authorizations for logical access to information and system resources in accordance with applicable access control policies.

    To mitigate the risk of unauthorized access to sensitive information by entities that have been issued certificates by DoD-approved PKIs, all DoD systems (e.g., networks, web servers, and web porta...
    Rule Medium Severity
  • SRG-APP-000038

    Group
  • Innoslate must enforce approved authorizations for controlling the flow of information within the system based on organization-defined information flow control policies.

    A mechanism to detect and prevent unauthorized communication flow must be configured or provided as part of the system design. If information flow is not enforced based on approved authorizations, ...
    Rule Medium Severity
  • SRG-APP-000070

    Group
  • The publicly accessible application must display the Standard Mandatory DoD Notice and Consent Banner before granting access to Innoslate.

    Display of a standardized and approved use notification before granting access to the publicly accessible application ensures privacy and security notification verbiage used is consistent with appl...
    Rule Medium Severity