Skip to content

II - Mission Support Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000108-NDM-000232

    <GroupDescription></GroupDescription>
    Group
  • The SEL-2740S must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000125-NDM-000241

    <GroupDescription></GroupDescription>
    Group
  • The SEL-2740S must be configured to send log data to a Syslog server or collected by another parent OTSDN Controller.

    &lt;VulnDiscussion&gt;Protection of log data includes assuring log data is not accidentally lost or deleted. Regularly backing up audit records to ...
    Rule Medium Severity
  • SRG-APP-000371-NDM-000296

    <GroupDescription></GroupDescription>
    Group
  • The SEL-2740S must be configured to compare internal information system clocks at least every 24 hours with an authoritative time server.

    &lt;VulnDiscussion&gt;Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the cor...
    Rule Medium Severity
  • SRG-APP-000372-NDM-000297

    <GroupDescription></GroupDescription>
    Group
  • The SEL-2740S must be configured to synchronize internal system clocks with an authoritative time source.

    &lt;VulnDiscussion&gt;Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the cor...
    Rule Medium Severity
  • SRG-APP-000373-NDM-000298

    <GroupDescription></GroupDescription>
    Group
  • The SEL-2740S must be configured to maintain internal system clocks with a backup authoritative time server.

    &lt;VulnDiscussion&gt;The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...
    Rule Medium Severity