Skip to content

III - Administrative Public

Rules and Groups employed by this XCCDF Profile

  • SRG-NET-000041-VPN-000110

    Group
  • The ICS must display the Standard Mandatory DOD Notice and Consent Banner before granting access to users.

    Display of the DOD-approved use notification before granting access to the network device ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executi...
    Rule Medium Severity
  • SRG-NET-000053-VPN-000170

    Group
  • The ICS must be configured to limit the number of concurrent sessions for user accounts to one.

    VPN gateway management includes the ability to control the number of users and user sessions that utilize a VPN gateway. Limiting the number of allowed users and sessions per user is helpful in lim...
    Rule Medium Severity
  • SRG-NET-000062-VPN-000200

    Group
  • The ICS must be configured to use TLS 1.2, at a minimum.

    Using older unauthorized versions or incorrectly configuring protocol negotiation makes the gateway vulnerable to known and unknown attacks that exploit vulnerabilities in this protocol. NIST SP 8...
    Rule High Severity
  • SRG-NET-000078-VPN-000290

    Group
  • The ICS must be configured to generate log records containing sufficient information about where, when, identity, source, or outcome of the events.

    Without establishing when events occurred, it is impossible to establish, correlate, and investigate the events leading up to an outage or attack. VPN gateways often have a separate audit log for ...
    Rule Low Severity
  • SRG-NET-000138-VPN-000490

    Group
  • The ICS must be configured to uniquely identify and authenticate organizational users (or processes acting on behalf of organizational users).

    To ensure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to prevent potential misuse and compromise of the system. Organizational user...
    Rule Medium Severity