Skip to content

I - Mission Critical Public

Rules and Groups employed by this XCCDF Profile

  • SRG-NET-000019-FW-000004

    Group
  • The Cisco ASA must immediately use updates made to policy enforcement mechanisms such as firewall rules, security policies, and security zones.

    Information flow policies regarding dynamic information flow control include, for example, allowing or disallowing information flows based on changes to the Ports, Protocols, Services Management (P...
    Rule Medium Severity
  • SRG-NET-000061-FW-000001

    Group
  • The Cisco ASA must be configured to restrict VPN traffic according to organization-defined filtering rules.

    Remote access devices (such as those providing remote access to network devices and information systems) that lack automated capabilities increase risk and make remote user access management diffic...
    Rule Medium Severity
  • SRG-NET-000074-FW-000009

    Group
  • The Cisco ASA must be configured to generate traffic log entries containing information to establish what type of events occurred.

    Without establishing what type of event occurred, it would be difficult to establish, correlate, and investigate the events leading up to an outage or attack. Audit event content that may be neces...
    Rule Medium Severity
  • SRG-NET-000075-FW-000010

    Group
  • The Cisco ASA must be configured to generate traffic log entries containing information to establish when (date and time) the events occurred.

    Without establishing when events occurred, it is impossible to establish, correlate, and investigate the events leading up to an outage or attack. In order to compile an accurate risk assessment, ...
    Rule Medium Severity
  • SRG-NET-000089-FW-000019

    Group
  • The Cisco ASA must be configured to queue log records locally in the event that the central audit server is down or not reachable.

    It is critical that when the network element is at risk of failing to process traffic logs as required, it takes action to mitigate the failure. Audit processing failures include software/hardware ...
    Rule Medium Severity