North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) cybersecurity standards profile for the Red Hat OpenShift Container Platform - Platform level
Rules and Groups employed by this XCCDF Profile
-
Kubernetes Settings
Each section of this configuration guide includes information about the configuration of a Kubernetes cluster and a set of recommendations for hard...Group -
System and Software Integrity
System and software integrity can be gained by installing antivirus, increasing system encryption strength with FIPS, verifying installed software,...Group -
Ensure that Cluster Version Operator is deployed
Integrity of the OpenShift platform is handled to start by the cluster version operator. Cluster Version Operator will by default GPG verify the in...Rule Medium Severity -
Ensure that Cluster Version Operator verifies integrity
Integrity of the OpenShift platform is handled to start by the cluster version operator. Cluster Version Operator will by default GPG verify the in...Rule Medium Severity -
Ensure that File Integrity Operator is scanning the cluster
<a href="https://docs.openshift.com/container-platform/4.7/security/file_integrity_operator/file-integrity-operator-understanding.html">The File In...Rule Medium Severity -
System Cryptographic Policies
OpenShift has the capability to centrally configure cryptographic polices.Group -
Ensure that FIPS mode is enabled on all cluster nodes
OpenShift has an installation-time flag that can enable FIPS mode for the cluster. The flag <pre>fips: true</pre> must be enabled at install time i...Rule High Severity -
Kubernetes - Account and Access Control
In traditional Unix security, if an attacker gains shell access to a certain login account, they can perform any action or access any file to which...Group -
Restrict Automounting of Service Account Tokens
Service accounts tokens should not be mounted in pods except where the workload running in the pod explicitly needs to communicate with the API ser...Rule Medium Severity -
Ensure Usage of Unique Service Accounts
Using the <code>default</code> service account prevents accurate application rights review and audit tracing. Instead of <code>default</code>, crea...Rule Medium Severity
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.
Capacity
Modules