MarkLogic Server must implement NIST FIPS 140-2 or 140-3 validated cryptographic modules to protect unclassified information requiring confidentiality and cryptographic protection, in accordance with the requirements of the data owner.
An XCCDF Rule
Description
<VulnDiscussion>Use of weak or untested encryption algorithms undermines the purposes of utilizing encryption to protect data. The application must implement cryptographic modules adhering to the higher standards approved by the federal government since this provides assurance they have been tested and validated. It is the responsibility of the data owner to assess the cryptography requirements in light of applicable federal laws, Executive Orders, directives, policies, regulations, and standards. For detailed information, refer to NIST FIPS Publication 140-2 or Publication 140-3, Security Requirements for Cryptographic Modules. Note that the product's cryptographic modules must be validated and certified by NIST as FIPS-compliant.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-220416r879885_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
Configure MarkLogic to use NIST FIPS validated cryptographic modules to provide cryptographic protection for the unclassified information that requires it.
Perform the fix from the MarkLogic Server Admin Interface with a user that holds administrative-level privileges.
1. Click the Clusters icon.
2. Click the local cluster.