The Juniper EX switch must be configured to generate an immediate real-time alert of all audit failure events requiring real-time alerts.
An XCCDF Rule
Description
<VulnDiscussion>It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-253919r879733_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
Configure the network device to generate an immediate real-time alert of all audit failure events requiring real-time alerts.
set chassis disk-partition /var level full free-space <0..100>
set chassis disk-partition /var level full free-space percent
set chassis disk-partition /var level high free-space <0..100>
set chassis disk-partition /var level high free-space percent