The IBM z/OS SNTP daemon (SNTPD) must be active.
An XCCDF Rule
Description
<VulnDiscussion>Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-223774r877038_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
Obtain a copy of this sample procedure from SEZAINST and store it in one of your PROCLIB concatenation data sets.
Perform the following step to start SNTPD as a procedure:
Invoke the procedure using the system operator start command. The following sample, SEZAINST(SNTPD), shows how to start SNTPD as a procedure:
//*
//* Sample procedure for the Simple Network Time Protocol (SNTP)