Skip to content

The Workspace ONE UEM server must be configured with a periodicity for reachable events of six hours or less for the following commands to the agent: - query connectivity status; - query the current version of the MD firmware/software; - query the current version of installed mobile applications; - read audit logs kept by the MD.

An XCCDF Rule

Description

<VulnDiscussion>Key security-related status attributes must be queried frequently so the Workspace ONE UEM server can report status of devices under management to the administrator and management. The periodicity of these queries must be configured to an acceptable timeframe. Six hours or less is considered acceptable for normal operations. SFR ID: FMT_SMF.1.1(2) c.3</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-221642r588007_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

Configure the Workspace ONE UEM server with a periodicity for reachable events of six hours or less for the following commands to the agent:
- query connectivity status;
- query the current version of the MD firmware/software;
- query the current version of installed mobile applications.

On the MDM console, do the following: