Skip to content

MobileIron Sentry must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes.

An XCCDF Rule

Description

<VulnDiscussion>By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-250986r802180_rule
Severity
Low
References
Updated



Remediation - Manual Procedure

Configure MobileIron Sentry to enforce the limit of three consecutive invalid login attempts during a 15-minute time period.

1. Log in to MobileIron Sentry System Manager portal.
2. Go to the "Security" tab.
3. Go to "Password Policy".
4. For "Number of Failed Attempts", set value to 3.