The Sentry must produce audit records containing information to establish what type of events occurred.
An XCCDF Rule
Description
<VulnDiscussion>Without establishing what type of event occurred, it would be difficult to establish, correlate, and investigate the events leading up to an outage or attack. Audit record content that may be necessary to satisfy this requirement includes, for example, event descriptions, success/fail indications, filenames involved, and access control or flow control rules invoked. Associating event types with detected events in the gateway logs provides a means of investigating an attack, recognizing resource utilization or capacity thresholds, or identifying an improperly configured network element. This requirement does not apply to audit logs generated on behalf of the device itself (management).</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-251015r802267_rule
- Severity
- Low
- References
- Updated
Remediation - Manual Procedure
Configure the Sentry to produce audit records containing information to establish what type of events occurred.
1. Log in to MobileIron Sentry.
2. Go to Settings >> Syslog.
3. Configure a new Syslog Server if not already added.
4. Click on the syslog server(s) and in the "Modify Syslog"/"Add Syslog" pop-up dialog, under the "Facility Type", click the checkbox for "Audit".