ISEC7 EMM Suite v6.x Security Technical Implementation Guide
SRG-APP-000635
SRG-APP-000635
An XCCDF Group - A logical subset of the XCCDF Benchmark
Details
Profiles
Prose
SRG-APP-000635
1 Rule
<GroupDescription></GroupDescription>
The ISEC7 EMM Suite must use a FIPS 140-2-validated cryptographic module to implement encryption services for unclassified information requiring confidentiality, generate cryptographic hashes, and to configure web management tools with FIPS-validated Advanced Encryption Standard (AES) cipher block algorithm to protect the confidentiality of maintenance and diagnostic communications for nonlocal maintenance sessions.
Medium Severity
<VulnDiscussion>FIPS 140-2 precludes the use of invalidated cryptography for the cryptographic protection of sensitive or valuable data within Federal systems. Unvalidated cryptography is viewed by NIST as providing no protection to the information or data. In effect, the data would be considered unprotected plaintext. If the agency specifies that the information or data be cryptographically protected, then FIPS 140-2 is applicable. In essence, if cryptography is required, it must be validated. Cryptographic modules that have been approved for classified use may be used in lieu of modules that have been validated against the FIPS 140-2 standard. The cryptographic module used must have one FIPS-validated encryption algorithm (i.e., validated Advanced Encryption Standard [AES]). This validated algorithm must be used for encryption for cryptographic security function within the product being evaluated. EMM Suite is using the standard JCE module coming with OpenJDK 11 (included in installer) or Oracle JRE either legacy 1.8 or latest release. see https://openjdk.java.net/groups/security/ There are two module providers, IBM and RSA. The check/fix are written assuming the RSA module is used. Any FIPS 140-2 compliant JCE module (.jar) can be replaced and configured and used with EMM Suite.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>