In the event of a system failure, the Infoblox system must preserve any information necessary to determine cause of failure and any information necessary to return to operations with least disruption to mission processes.
An XCCDF Rule
Description
<VulnDiscussion>Failure to a known state can address safety or security in accordance with the mission/business needs of the organization. Preserving application state information helps to facilitate application restart and return to the operational mode of the organization with less disruption to mission-essential processes.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-233920r621666_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
1. Navigate to Grid >> Grid Manager >> Grid Properties, or System >> System Manager >> System Properties if using a stand-alone configuration.
2. Select the "Monitoring" tab.
3. Enable "Log to External Syslog Server" and configure at least one External Syslog Server.
4. Enable the option "Copy Audit Log Message to Syslog".
5. Click "Save & Close" to save the changes and exit the "Properties" screen.
6. Perform a service restart if necessary.