The HP FlexFabric Switch must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

An XCCDF Rule

Description

<VulnDiscussion>Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-80745r1_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

Configure timestamp on the logs on the HP FlexFabric Switch:

[HP] info-center timestamp date

By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY which provides required granularity.