Skip to content

The HP FlexFabric Switch must use internal system clocks to generate time stamps for audit records.

An XCCDF Rule

Description

<VulnDiscussion>In order to determine what is happening within the network infrastructure or to resolve and trace an attack, the HP FlexFabric Switch must support the organization's capability to correlate the audit log data from multiple network devices to acquire a clear understanding of events. In order to correlate auditable events, time stamps are needed on all of the log records. If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose. (Note that the internal clock is required to be synchronized with authoritative time sources by other requirements.)</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-80679r1_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

Configure the HP FlexFabric Switch to use internal system clocks to generate time stamps for audit records.
<HP> clock datetime 06:13:00 08/05/2015