The A10 Networks ADC must generate an alert to, at a minimum, the ISSO and ISSM when threats identified by authoritative sources (e.g., IAVMs or CTOs) are detected.
An XCCDF Rule
Description
<VulnDiscussion>Without an alert, security personnel may be unaware of major detection incidents that require immediate action and this delay may result in the loss or compromise of information. The device generates an alert which notifies designated personnel of the Indicators of Compromise (IOCs) which require real-time alerts. These messages should include a severity level indicator or code as an indicator of the criticality of the incident. These indicators reflect the occurrence of a compromise or a potential compromise. Since these incidents require immediate action, these messages are assigned a critical or level 1 priority/severity, depending on the system's priority schema. Alerts may be transmitted, for example, telephonically, by electronic mail messages, or by text messaging. The device must either send the alert to a management console that is actively monitored by authorized personnel or use a messaging capability to send the alert directly to designated personnel.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-237055r639612_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
These are two of the three possible methods of notification that can be configured.
The following command enables SNMP traps:
snmp-server enable traps