Skip to content

The VMM must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

An XCCDF Rule

Description

<VulnDiscussion>Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the VMM include date and time. Granularity of time measurements refers to the degree of synchronization between VMM clocks and reference clocks.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-207465r958786_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

Configure the VMM to record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.