Vault/Secure Room Storage Standards - Automated Entry Control System (AECS) and Intrusion Detection System (IDS) Head-End Equipment Protection: The physical location (room or area) containing AECS and IDS head-end equipment (server and/or work station/monitoring equipment) where authorization, personal identification or verification data is input, stored, or recorded and/or where system status/alarms are monitored must be physically protected.

An XCCDF Rule

Description

<VulnDiscussion>Inadequate physical protection of Intrusion Detection System or Automated Entry Control System servers, data base storage drives, or monitoring work stations could result in unauthorized access to core system devices providing protection for classified vaults, secure rooms and collateral classified open storage areas. This could result in the loss of confidentiality, integrity or availability of system functionality or data. The impact of this would be possible undetected and unauthorized access to classified processing spaces; resulting in the loss or compromise of classified information or sensitive information such as personal data (PII) of persons issued access control cards or badges. REFERENCES: The Information Security Oversight Office (ISOO): http://www.archives.gov/isoo/ Implementing Directive for Protection of Classified (for Executive Order 13526), 32 CFR Parts 2001 and 2003 Classified National Security Information: paragraph 2001.43 Storage, (2) Secret. CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraphs 24.j. and 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: MP-4, PE-1, PE-2, PE-3, PE-6, PE-8 and PE-9. DoD Manual 5200.01, Volume 3, SUBJECT: DoD Information Security Program: Protection of Classified Information: Appendix to Enclosure 3, paragraphs 2.f.(2), 3.a(5). and 3.a.(6). DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016, paragraphs 5-313. e. and 5-313 h.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-245809r822865_rule
Severity
High
Updated



Remediation - Manual Procedure

1. The physical location containing the primary IDS "head-end" equipment (server and/or work station/monitoring equipment) must be located in a continuously occupied location (e.g., guard monitoring station for alarms and CCTV).  

2. The continuously occupied space must limit unescorted access to only those employees responsible for monitoring or controlling the IDS and/or AECS.  Automated entry control system card/badge readers or cipher locks should be used to fulfill this requirement.  

3.  If not co-located with the IDS "head-end" equipment; the physical location containing the primary AECS "head-end" equipment must be located in a continuously occupied location OR protected minimally within a room with a BMS alarm contact on each door, window or opening and with interior motion detection sensors that are activated at the end of each duty day.