Skip to content

TOSS must, for networked systems, compare internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant United States Naval Observatory (USNO) time servers, or a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS).

An XCCDF Rule

Description

<VulnDiscussion>Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time that a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the operating system include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. TOSS utilizes the "timedatectl" command to view the status of the "systemd-timesyncd.service." The "timedatectl" status will display the local time, UTC, and the offset from UTC. Note that USNO offers authenticated NTP service to DOD and U.S. Government agencies operating on the NIPR and SIPR networks. Visit https://www.usno.navy.mil/USNO/time/ntp/dod-customers for more information. Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144, SRG-OS-000359-GPOS-00146</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-252928r986576_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

For networked systems, configure TOSS to compare internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant USNO time servers, or a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the GPS.

Add and/or modify the following line in the /etc/chrony.conf file:

server [ntp.server.name] iburst maxpoll 16