The Tanium Operating System (TanOS) must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
An XCCDF Rule
Description
<VulnDiscussion>The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes it's time to a more accurate source. The system must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. Organizations should also consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: A time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-254867r1015860_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
1. Access the Tanium Server interactively.
2. Log on to the TanOS server with the tanadmin role.
3. Press "A" for "Appliance Configuration Menu," and then press "Enter".