AIX must provide time synchronization applications that can synchronize the system clock to external time sources at least every 24 hours.
An XCCDF Rule
Description
<VulnDiscussion>Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-215208r1009533_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
Edit /etc/ntp.conf
Configure ntp server by adding the following line:
server server_ipaddr
Set maxpoll to <value> <=16 by adding the maxpoll <value>.