Skip to content

The application server must compare internal application server clocks at least every 24 hours with an authoritative time source.

An XCCDF Rule

Description

<VulnDiscussion>Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronization of system clocks is needed to correctly correlate the timing of events that occur across multiple systems. To meet this requirement, the organization will define an authoritative time source and have each system compare its internal clock at least every 24 hours.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-204792r981685_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

Configure the application server to compare internal application server clocks at least every 24 hours with an authoritative time source.