Skip to content

BMC IOA is not properly defined to the Facility Matrix Table for Top Secret.

An XCCDF Rule

Description

<VulnDiscussion>Improperly defined security controls for BMC IOA could result in the compromise of the network, operating system, and customer data.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-224605r518955_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

The BMC IOA system programmer and the IAO will ensure that the TOP SECRET Facility Matrix Table is proper defined using the following example:

IOA:
FACILITY(USERxx=NAME=IOA,PGM=IOA,ID=nn,ACTIVE,SHRPRF)
FACILITY(IOA=ASUBM,NOABEND,MULTIUSER,NOXDEF)
FACILITY(IOA=LUMSG,STMSG,SIGN(S),NORNDPW)