Skip to content

BMC CONTROL-O STC data sets must be properly protected.

An XCCDF Rule

Description

<VulnDiscussion>BMC CONTROL-O STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-224411r518850_rule
Severity
Medium
References
Updated



Remediation - Manual Procedure

The ISSO will ensure that WRITE and/or greater access to BMC CONTROL-O STC data sets are limited to System Programmers only.  UPDATE access can be given to BMC users and the BMC STCs and/or batch users.  READ access can be given to auditors, operators, and domain level production control and scheduling personnel.

The installing systems programmer will identify and document the product data sets and categorize them according to who will have what type of access and if required which type of access is logged.  The installing systems programmer will identify any additional groups requiring access to specific data sets, and once documented the installing systems programmer will work with the ISSO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be: 
SYS3.IOA.*.CTOO.**