Vault/Secure Room Storage Standards - Intrusion Detection System and Automated Entry Control System (IDS/AECS) Component Tamper Protection
An XCCDF Rule
Description
<VulnDiscussion>Failure to tamper protect IDS/AECS component enclosures and access points external to protected vaults/secure rooms space could result in the undetected modification or disabling of IDS/AECS system components. This could lead to the undetected breach of secure space containing SIPRNet assets and result in the undetected loss or compromise of classified information or materials. REFERENCES: The Information Security Oversight Office (ISOO): http://www.archives.gov/isoo/ Implementing Directive for Protection of Classified (for Executive Order 13526), 32 CFR Parts 2001 and 2003 Classified National Security Information: paragraph 2001.43 Storage, (2) Secret. CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: MP-4, PE-3, PE-5, PE-6(1) DoD Manual 5200.01, Volume 3, SUBJECT: DoD Information Security Program: Protection of Classified Information: Appendix to Enclosure 3, paragraphs 2.d.(8 and 3.a.(5)(b). DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016, Chapter 5, Section 9. Intrusion Detection Systems and Section 3. AECS paragraph 5-313.f.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-245815r822872_rule
- Severity
- Medium
- Updated
Remediation - Manual Procedure
Requirements Summary:
Protection must be established and maintained for all component devices or equipment that constitute the Automated Entry Control System (AECS) and/or the Intrusion Detection System (IDS) used to protect a vault, secure room or collateral classified open storage area, which contains SIPRNet assets.
If access to a junction box or controller will enable an unauthorized modification, then alarmed tamper protection, which is normally provided by a pressure sensitive switch must be used.