Vault/Secure Room Storage Standards - IDS Transmission Line Security

An XCCDF Rule

Description

<VulnDiscussion>Failure to meet standards for ensuring integrity of the intrusion detection system signal transmission supporting a secure room (AKA: collateral classified open storage area) containing SIPRNet assets could result in the undetected loss or compromise of classified material. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: MP-4, PE-3, PE-5 and PE-6 DoD Manual 5200.01, Volume 3, SUBJECT: DoD Information Security Program: Protection of Classified Information: Appendix to Enclosure 3, paragraph 2.d.(1) and (2). DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016, paragraph 5-904.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-245805r822857_rule
Severity
High
Updated



Remediation - Manual Procedure

Explanation of requirement:

Transmission lines used to carry IDS sensor alarm signals between secure rooms or areas containing SIPRNet assets and IDS monitoring equipment, shall have line supervision.

If all portions of an IDS transmission line (protecting SIPRNet assets) are run within secret or higher secure area space or secret or higher controlled access area (CAA) spaces it will not require line supervision.