XCCDF
Traditional Security Checklist
IS-02.01.09
IS-02.01.09
An XCCDF Group - A logical subset of the XCCDF Benchmark
Details
Profiles
Prose
IS-02.01.09
1 Rule
<GroupDescription></GroupDescription>
Information Security (INFOSEC) - Secure Room Storage Standards - Interior Motion Detection
High Severity
<VulnDiscussion>Failure to meet standards for ensuring that there is structural integrity of the physical perimeter surrounding a secure room (AKA: collateral classified open storage area) IAW DoD Manual 5200.01, Volume 3 could result in the undetected loss or compromise of classified material. Motion detection located interior to secure rooms provides the most complete/overarching coverage of any Intrusion Detection System (IDS) alarm sensor. While most sensors like BMS alarm contacts, glass break detectors, etc. are only able to detect potential intrusion at specific locations, use of motion detection provides a capability to protect large areas with "blanket coverage" generally using fewer sensors. Principles and considerations for "ideal" employment of motion sensors are: - Consolidate critical assets in specific areas versus throughout a large room or facility. For instance rather than having classified servers and equipment in multiple locations in a five-story facility (entirely designated for classified open storage) consolidate classified assets on a single floor or even an area on that floor. That might allow for reducing the space designated as classified open storage (AKA: secure room) and reduce costs and simplify protection of assets. - Conversely some would argue that dispersing assets over a larger area enhances security by not putting all critical assets in one place. This is true to an extent - especially if we are considering redundant assets for COOP / disaster recovery but most often the reason for dispersing classified assets over large comes down to lack of foresight and planning. - Cover avenues of approach in layers so you can detect initial breeches of secured space and subsequent movement within. This approach is actually very good if you have a timely response force available and you are protecting a large facility. - Cover perimeter access points such as doors, windows, and openings greater than 96 sq. inches. Use of point sensors (BMS, vibration, etc., are probably best in these situations but supplementation by motion can be extremely effective. - Cover areas that cannot be directly observed by employees from within or directly outside the protected space. For instance in a secure room/area this might include areas above suspended ceilings, below raised floors, behind major pieces of equipment or other things that cause significant obstruction of visual observation (especially along avenues of approach or along perimeter walls). - Cover large open areas by careful placement of motion detection. Combinations of 360-degree and wall-mounted detectors considering equipment racks, walls, avenues of approach, etc. can effectively cover larger areas with fewer sensors. - Complete coverage of large areas and all avenues of approach is ideal but often funds are limited and sensors cannot be employed to provide blanket coverage. In such instances there are two approaches that can be used: * One is to cover the most critical assets directly (e.g., classified DoDIN servers, routers, DASD and other major IT technology). * Second approach is to conduct an assessment of the space to determine the most effective employment of limited sensors considering both avenues of approach and the actual location of critical assets in the space. NOTE: The second approach can be incorporated under the process of conducting a risk assessment and in conjunction with a determination and approval of security-in-depth countermeasures from the Senior Agency Official (SAO). This risk-based approach is based directly on requirements from the DoD Manual 5200.01, V3 and is in line with the current direction DoD is taking with regard to management of risk. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraphs 24.j. and 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: MP-4, PE-3, PE-5 and PE-6 DoD Manual 5200.01, Volume 3, SUBJECT: DoD Information Security Program: Protection of Classified Information: Appendix to Enclosure 3, paragraph 1.b.(4)(a) and 2.e.(3) & (5). The Information Security Oversight Office (ISOO): http://www.archives.gov/isoo/ Implementing Directive for Protection of Classified (for Executive Order 13526), 32 CFR Parts 2001 and 2003 Classified National Security Information: paragraph 2001.43 Storage, (2) Secret. DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016, Chapter 5, Section 9. Intrusion Detection Systems.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>