Protected Distribution System (PDS) Construction - External Suspended PDS

An XCCDF Rule

Description

<VulnDiscussion>Suspended carriers (Exterior PDS) are a Category 2 PDS option used to extend a PDS between Controlled Access Areas (CAAs) that are located in different buildings. Suspended carriers may be used for short runs when it is not practical to bury the PDS between buildings (e.g., between the 3rd floors of adjacent buildings). Unlike other Category 2 PDS the unencrypted data cables are not required to be installed in a carrier. Proper elevation and ease of visibility as well as minimum daily visual inspections of suspended carriers is of paramount importance. A PDS that is not configured, physically secured and inspected as required could result in the undetected interception of classified information. This is especially true for unencrypted cables running through an outdoor environment where physical barriers protecting the environment are often easily breeched. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 35.c. DoD 5220.22-M (NISPOM), Incorporating Change 2, 18 May 2016 Chapter 5, Section 4, paragraphs 5-402.c. and 5-403 DoD Manual 5200.01, Volume 3, 24 February 2012, SUBJECT: DoD Information Security Program: Protection of Classified Information, Encl 4, para 3.b. and 4.a. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: PE-4, SC-7, and SC-8 DoD 5220.22-M (NISPOM), Chapter 5, paragraphs 5-402. (c) and 5-403. (a). CNSSI No. 7003, September 2015, Protected Distribution Systems (PDS), Section IV, paragraph 7 and Section X, paragraph 30.c.</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>

ID
SV-245732r822799_rule
Severity
High
Updated



Remediation - Manual Procedure

Suspended carriers may only be used for short runs when it is not practical to bury the PDS between buildings (e.g., between the 3rd floors of adjacent buildings). 
Ensure that:

1. Suspended carriers between buildings are permissible if they terminate in a CAA on each end or immediately enter a hardened PDS at the building boundary. 

2. The suspended carrier must be hung directly between buildings.