Automation Controller must compare internal application server clocks at least every 24 hours with an authoritative time source.
An XCCDF Rule
Description
<VulnDiscussion>When conducting forensic analysis and investigating system events, it is critical that timestamps accurately reflect the time of application events. If timestamps are not deemed to be accurate, the integrity of the forensic analysis and the associated determinations are at stake. This leaves the organization and the system vulnerable to intrusions. Satisfies: SRG-APP-000371-AS-000077, SRG-APP-000372-AS-000212</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-256909r902297_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
As a system administrator, for each Automation Controller host, configure the NTP client to synchronize to an organizationally defined NTP server:
vi /etc/chrony.conf
Restart the Automation Controller host: