Automation Controller must allocate log record storage capacity and shut down by default upon log failure (unless availability is an overriding concern).
An XCCDF Rule
Description
<VulnDiscussion>It is critical that when a system is at risk of failing to process logs, it detects and takes action to mitigate the failure. Log processing failures include software/hardware errors, failures in the log capturing mechanisms, and log storage capacity being reached or exceeded. During a failure, the application server must be configured to shut down unless the application server is part of a high availability system. When availability is an overriding concern, other approved actions in response to a log failure are as follows: (i) If the failure was caused by the lack of log record storage capacity, the application must continue generating log records if possible (automatically restarting the log service if necessary), overwriting the oldest log records in a first-in-first-out manner. (ii) If log records are sent to a centralized collection server and communication with this server is lost or the server fails, the application must queue log records locally until communication is restored or until the log records are retrieved manually. Upon restoration of the connection to the centralized collection server, action must be taken to synchronize the local log data with the collection server. Satisfies: SRG-APP-000109-AS-000068, SRG-APP-000357-AS-000038</VulnDiscussion><FalsePositives></FalsePositives><FalseNegatives></FalseNegatives><Documentable>false</Documentable><Mitigations></Mitigations><SeverityOverrideGuidance></SeverityOverrideGuidance><PotentialImpacts></PotentialImpacts><ThirdPartyTools></ThirdPartyTools><MitigationControl></MitigationControl><Responsibility></Responsibility><IAControls></IAControls>
- ID
- SV-256901r927265_rule
- Severity
- Medium
- References
- Updated
Remediation - Manual Procedure
Open a web browser and navigate to: https://<Automation Controller server>/api/v2/settings/logging/
(If the "Log In" button is displayed, click it, enter an Automation Controller administrator's credentials, and continue.)
In the Content section, modify the following values: