Juniper Router NDM Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000038-NDM-000213

    <GroupDescription></GroupDescription>
    Group
  • The Juniper router must be configured to enforce approved authorizations for controlling the flow of management information within the device based on control policies.

    &lt;VulnDiscussion&gt;A mechanism to detect and prevent unauthorized communication flow must be configured or provided as part of the system design...
    Rule Medium Severity
  • SRG-APP-000065-NDM-000214

    <GroupDescription></GroupDescription>
    Group
  • The Juniper router must be configured to enforce the limit of three consecutive invalid logon attempts after which time lock out the user account from accessing the device for 15 minutes.

    &lt;VulnDiscussion&gt;By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise...
    Rule Medium Severity
  • SRG-APP-000068-NDM-000215

    <GroupDescription></GroupDescription>
    Group
  • SRG-APP-000080-NDM-000220

    <GroupDescription></GroupDescription>
    Group
  • SRG-APP-000133-NDM-000244

    <GroupDescription></GroupDescription>
    Group
  • The Juniper router must be configured to protect against an individual falsely denying having performed organization-defined actions to be covered by non-repudiation.

    &lt;VulnDiscussion&gt;This requirement supports non-repudiation of actions taken by an administrator and is required in order to maintain the integ...
    Rule Medium Severity
  • SRG-APP-000091-NDM-000223

    <GroupDescription></GroupDescription>
    Group
  • The Juniper router must be configured to generate audit records when successful/unsuccessful attempts to logon with access privileges occur.

    &lt;VulnDiscussion&gt;Without generating audit records that are specific to the security and mission needs of the organization, it would be difficu...
    Rule Medium Severity