Skip to content

Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • MobileIron Sentry must limit the number of concurrent sessions for the CLISH interface to an organization-defined number for each administrator account and/or administrator account type.

    Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administr...
    Rule Medium Severity
  • MobileIron Sentry must be configured to limit the network access of the Sentry System Manager Portal behind the corporate firewall and whitelist source IP range.

    Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administr...
    Rule Medium Severity
  • MobileIron Sentry must enforce approved authorizations for controlling the flow of management information within the network device based on information flow control policies.

    A mechanism to detect and prevent unauthorized communication flow must be configured or provided as part of the system design. If management information flow is not enforced based on approved autho...
    Rule Low Severity
  • MobileIron Sentry device must enforce a minimum 15-character password length.

    Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. Password length is one factor of several that helps to d...
    Rule Medium Severity
  • MobileIron Sentry must enforce password complexity by requiring that at least one upper-case character be used.

    Use of a complex passwords helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resisti...
    Rule Medium Severity
  • MobileIron Sentry must enforce password complexity by requiring that at least one numeric character be used.

    Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resistin...
    Rule Medium Severity
  • MobileIron Sentry, for PKI-based authentication, must be configured to map validated certificates to unique user accounts.

    Without mapping the PKI certificate to a unique user account, the ability to determine the identities of individuals or the status of their non-repudiation is considerably impacted during forensic ...
    Rule High Severity
  • MobileIron Sentry must terminate all network connections associated with a device management session at the end of the session, or the session must be terminated after 10 minutes of inactivity except to fulfill documented and validated mission requirement.

    Terminating an idle session within a short time period reduces the window of opportunity for unauthorized personnel to take control of a management session enabled on the console or console port th...
    Rule High Severity
  • MobileIron Sentry must be configured to synchronize internal information system clocks using redundant authoritative time sources.

    The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other ...
    Rule Medium Severity
  • MobileIron Sentry must be configured to implement cryptographic mechanisms using a FIPS 140-2 approved algorithm to protect the confidentiality of remote maintenance sessions.

    This requires the use of secure protocols instead of their unsecured counterparts, such as SSH instead of telnet, SCP instead of FTP, and HTTPS instead of HTTP. If unsecured protocols (lacking cryp...
    Rule High Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.