SRG-OS-000080
Group -
BMC MAINVIEW for z/OS installation data sets are not properly protected.
BMC MAINVIEW for z/OS installation data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result i...Rule Medium Severity -
SRG-OS-000259
Group -
BMC MAINVIEW for z/OS STC data sets are not properly protected.
BMC MAINVIEW for z/OS STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violati...Rule Medium Severity -
SRG-OS-000018
Group -
BMC MAINVIEW resources must be properly defined and protected.
BMC MAINVIEW can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control access to product resources could result in the compromise of the ...Rule Medium Severity -
SRG-OS-000104
Group -
BMC Mainview for z/OS Started Task name is not properly identified and/or defined to the system ACP.
BMC Mainview for z/OS requires a started task that will be restricted to certain resources, datasets and other system functions. By defining the started task as a userid to the system ACP, It allow...Rule Medium Severity -
SRG-OS-000104
Group -
BMC Mainview for z/OS Started task(s) must be properly defined to the STARTED resource class for RACF.
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of pr...Rule Medium Severity -
SRG-OS-000309
Group -
BMC Mainview for z/OS Resource Class will be defined or active in the ACP.
Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS operating system and user data.Rule Medium Severity -
SRG-OS-000018
Group -
BMC MAINVIEW for z/OS configuration/parameter values are not specified properly.
BMC MAINVIEW for z/OS configuration/parameters controls the security and operational characteristics of products. If these parameter values are improperly specified, security and operational contr...Rule Medium Severity