  • SRG-APP-000495-NDM-000318

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records when successful/unsuccessful attempts to modify administrator privileges occur.

    &lt;VulnDiscussion&gt;Without generating audit records specific to the security and mission needs of the organization, it would be difficult to est...
    Rule Medium Severity
  • SRG-APP-000499-NDM-000319

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records when successful/unsuccessful attempts to delete administrator privileges occur.

    &lt;VulnDiscussion&gt;Without generating audit records specific to the security and mission needs of the organization, it would be difficult to est...
    Rule Medium Severity
  • SRG-APP-000503-NDM-000320

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records when successful/unsuccessful logon attempts occur.

    &lt;VulnDiscussion&gt;Without generating audit records that are specific to the security and mission needs of the organization, it would be difficu...
    Rule Medium Severity
  • SRG-APP-000504-NDM-000321

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records for privileged activities or other system-level access.

    &lt;VulnDiscussion&gt;Without generating audit records specific to the security and mission needs of the organization, it would be difficult to est...
    Rule Medium Severity
  • SRG-APP-000505-NDM-000322

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records showing starting and ending time for administrator access to the system.

    &lt;VulnDiscussion&gt;Without generating audit records specific to the security and mission needs of the organization, it would be difficult to est...
    Rule Medium Severity
  • SRG-APP-000506-NDM-000323

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records when concurrent logons from different workstations occur.

    &lt;VulnDiscussion&gt;Without generating audit records specific to the security and mission needs of the organization, it would be difficult to est...
    Rule Medium Severity
  • SRG-APP-000100-NDM-000230

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records containing information that establishes the identity of any individual or process associated with the event.

    &lt;VulnDiscussion&gt;Without information that establishes the identity of the subjects (i.e., administrators or processes acting on behalf of admi...
    Rule Medium Severity
  • SRG-APP-000101-NDM-000231

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must generate audit records containing the full-text recording of privileged commands.

    &lt;VulnDiscussion&gt;Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information. O...
    Rule Medium Severity
  • SRG-APP-000357-NDM-000293

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

    &lt;VulnDiscussion&gt;To ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to alloca...
    Rule Medium Severity
  • SRG-APP-000515-NDM-000325

    <GroupDescription></GroupDescription>
    Group
  • The FortiGate device must off-load audit records on to a different system or media than the system being audited.

    &lt;VulnDiscussion&gt;Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Offloading is a common ...
    Rule Medium Severity