The DBN-6300 must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.Rule Medium Severity -
SRG-APP-000375-NDM-000300
Group -
The DBN-6300 must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granula...Rule Medium Severity -
SRG-APP-000381-NDM-000305
Group -
The DBN-6300 must audit the enforcement actions used to restrict access associated with changes to the device.
Without auditing the enforcement of access restrictions against changes to the device configuration, it will be difficult to identify attempted attacks, and an audit trail will not be available for...Rule Medium Severity