Skip to content

I - Mission Critical Sensitive

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000378-NDM-000302

    Group
  • The Juniper SRX Services Gateway must implement logon roles to ensure only authorized roles are allowed to install software and updates.

    Allowing anyone to install software, without explicit privileges, creates the risk that untested or potentially malicious software will be installed on the system. This requirement applies to code ...
    Rule Medium Severity
  • SRG-APP-000516-NDM-000317

    Group
  • If the loopback interface is used, the Juniper SRX Services Gateway must protect the loopback interface with firewall filters for known attacks that may exploit this interface.

    The loopback interface is a logical interface and has no physical port. Since the interface and addresses ranges are well-known, this port must be filtered to protect the Juniper SRX from attacks.
    Rule Medium Severity