III - Administrative Public
Rules and Groups employed by this XCCDF Profile
-
SRG-APP-000516
Group -
The container platform must provide the configuration for organization-identified individuals or roles to change the auditing to be performed on all components, based on all selectable event criteria within organization-defined time thresholds.
Auditing requirements may change per organization or situation within and organization. With the container platform allowing an organization to customize the auditing, an organization can decide to...Rule Medium Severity -
SRG-APP-000357
Group -
The container platform must allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.
In order to ensure applications have a sufficient storage capacity in which to write the audit logs, applications need to be able to allocate audit record storage capacity. The task of allocating ...Rule Medium Severity -
SRG-APP-000358
Group -
Audit records must be stored at a secondary location.
Auditable events are used in the investigation of incidents and must be protected from being deleted or altered. Often, events that took place in the past must be viewed to understand the entire in...Rule Medium Severity -
SRG-APP-000359
Group -
The container platform must provide an immediate warning to the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of repository maximum audit record storage capacity.
If security personnel are not notified immediately upon storage volume utilization reaching 75 percent, they are unable to plan for storage capacity expansion.Rule Medium Severity -
SRG-APP-000360
Group -
The container platform must provide an immediate real-time alert to the SA and ISSO, at a minimum, of all audit failure events requiring real-time alerts.
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impe...Rule Medium Severity