Skip to content

No profile (default benchmark)

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000033

    <GroupDescription></GroupDescription>
    Group
  • Documentation identifying Tanium console users and their respective Computer Group rights must be maintained.

    &lt;VulnDiscussion&gt;System access should be reviewed periodically to verify all Tanium users are assigned the appropriate computer groups, with t...
    Rule Medium Severity
  • SRG-APP-000149

    <GroupDescription></GroupDescription>
    Group
  • Multifactor authentication must be enabled on the Tanium Server for network access with privileged accounts.

    &lt;VulnDiscussion&gt;The Tanium application must be configured to use multifactor authentication. Without the use of multifactor authentication, t...
    Rule High Severity
  • SRG-APP-000383

    <GroupDescription></GroupDescription>
    Group
  • Firewall rules must be configured on the Tanium Server for Console-to-Server communications.

    &lt;VulnDiscussion&gt;An HTML5-based application, the Tanium Console runs from any device with a browser that supports HTML5. For security, the HTT...
    Rule Medium Severity
  • SRG-APP-000068

    <GroupDescription></GroupDescription>
    Group
  • The publicly accessible Tanium application must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the application.

    &lt;VulnDiscussion&gt;Display of a standardized and approved use notification before granting access to the publicly accessible application ensures...
    Rule Medium Severity
  • SRG-APP-000108

    <GroupDescription></GroupDescription>
    Group
  • The Tanium application must alert the information system security officer and system administrator (at a minimum) in the event of an audit processing failure.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity