Rules and Groups employed by this XCCDF Profile

  • PP-MDF-323040

    <GroupDescription></GroupDescription>
    Group
  • Samsung Android must be configured to not allow more than 10 consecutive failed authentication attempts.

    &lt;VulnDiscussion&gt;The more attempts an adversary has to guess a password, the more likely the adversary will enter the correct password and gai...
    Rule Medium Severity
  • PP-MDF-323030

    <GroupDescription></GroupDescription>
    Group
  • Samsung Android must be configured to lock the display after 15 minutes (or less) of inactivity.

    &lt;VulnDiscussion&gt;The screen lock timeout must be set to a value that helps protect the device from unauthorized access. Having a too-long time...
    Rule Medium Severity
  • PP-MDF-323110

    <GroupDescription></GroupDescription>
    Group
  • Samsung Android must be configured to disable authentication mechanisms providing user access to protected data other than a Password Authentication Factor, including face recognition.

    &lt;VulnDiscussion&gt;The biometric factor can be used to authenticate the user to unlock the mobile device. Unapproved/evaluated biometric mechani...
    Rule Medium Severity
  • PP-MDF-323030

    <GroupDescription></GroupDescription>
    Group
  • Samsung Android must be configured to enable a screen-lock policy that will lock the display after a period of inactivity - Disable trust agents.

    &lt;VulnDiscussion&gt;The screen lock timeout must be set to a value that helps protect the device from unauthorized access. Having a too-long time...
    Rule Medium Severity
  • PP-MDF-323250

    <GroupDescription></GroupDescription>
    Group
  • Samsung Android must be configured to not allow backup of all applications and configuration data to remote systems. - Disable Backup Services.

    &lt;VulnDiscussion&gt;Backups to remote systems (including cloud backup) can leave data vulnerable to breach on the external systems, which often o...
    Rule Medium Severity