Skip to content

III - Administrative Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-OS-000138-GPOS-00069

    <GroupDescription></GroupDescription>
    Group
  • The sticky bit must be set on all SUSE operating system world-writable directories.

    &lt;VulnDiscussion&gt;Preventing unauthorized information transfers mitigates the risk of information, including encrypted representations of infor...
    Rule Medium Severity
  • SRG-OS-000142-GPOS-00071

    <GroupDescription></GroupDescription>
    Group
  • The SUSE operating system must be configured to use TCP syncookies.

    &lt;VulnDiscussion&gt;Denial of Service (DoS) is a condition in which a resource is not available for legitimate users. When this occurs, the organ...
    Rule Medium Severity
  • SRG-OS-000163-GPOS-00072

    <GroupDescription></GroupDescription>
    Group
  • The SUSE operating system for all network connections associated with SSH traffic must immediately terminate at the end of the session or after 10 minutes of inactivity.

    &lt;VulnDiscussion&gt;Automatic session termination addresses the termination of user-initiated logical sessions in contrast to the termination of ...
    Rule Medium Severity
  • SRG-OS-000185-GPOS-00079

    <GroupDescription></GroupDescription>
    Group
  • All SUSE operating system persistent disk partitions must implement cryptographic mechanisms to prevent unauthorized disclosure or modification of all information that requires at-rest protection.

    &lt;VulnDiscussion&gt;SUSE operating systems handling data requiring data-at-rest protections must employ cryptographic mechanisms to prevent unaut...
    Rule High Severity
  • SRG-OS-000205-GPOS-00083

    <GroupDescription></GroupDescription>
    Group
  • The SUSE operating system must generate error messages that provide information necessary for corrective actions without revealing information that could be exploited by adversaries.

    &lt;VulnDiscussion&gt;Any operating system providing too much information in error messages risks compromising the data and security of the structu...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules