Skip to content

III - Administrative Sensitive

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000133-DB-000362

    <GroupDescription></GroupDescription>
    Group
  • The role(s)/group(s) used to modify database structure (including but not necessarily limited to indexes, storage, etc.) and logic modules (functions, triggers, links to software external to the MarkLogic Server, etc.) must be restricted to authorized users.

    &lt;VulnDiscussion&gt;If the DBMS were to allow any user to make changes to database structure or logic, then those changes might be implemented wi...
    Rule Medium Severity
  • SRG-APP-000141-DB-000091

    <GroupDescription></GroupDescription>
    Group
  • Unused database components, DBMS software, and database objects must be removed.

    &lt;VulnDiscussion&gt;Information systems are capable of providing a wide variety of functions and services. Some of the functions and services, pr...
    Rule Medium Severity
  • SRG-APP-000141-DB-000093

    <GroupDescription></GroupDescription>
    Group
  • Access to external executables must be disabled or restricted.

    &lt;VulnDiscussion&gt;Information systems are capable of providing a wide variety of functions and services. Some of the functions and services, pr...
    Rule Medium Severity
  • SRG-APP-000142-DB-000094

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server must be configured to prohibit or restrict the use of organization-defined functions, ports, protocols, and/or services, as defined in the PPSM CAL and vulnerability assessments.

    &lt;VulnDiscussion&gt;In order to prevent unauthorized connection of devices, unauthorized transfer of information, or unauthorized tunneling (i.e....
    Rule Medium Severity
  • SRG-APP-000148-DB-000103

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server must uniquely identify and authenticate organizational users (or processes acting on behalf of organizational users).

    &lt;VulnDiscussion&gt;To ensure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to pre...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules